Service Price
Home Inspection (0–2,000 sq ft) $425
Home Inspection (2,000–3,000 sq ft) $500
Sewer Scope Inspection (with inspection) $200
Sewer Scope Inspection (standalone) $275
Thermal Imaging $40
Radon Quick Test $30
Crawl Space Inspection $50

SAMPLE HOME
INSPECTION REPORT

For Demonstration Purposes Only

Sample Home Exterior

Property Address

123 Main Street
Clovis, NM 88101

Inspection Date

July 22, 2025

Inspector

John Smith
Certified Home Inspector

Client

John Doe

This is a sample report preview. Actual inspection reports may vary based on property condition, age, location, accessibility, and requested services.

Inspection Summary

The property was visually inspected for readily accessible systems and components. The report includes photos, written observations, condition notes, and recommendations for repairs or further evaluation where needed.

Summary of Findings

2 High Priority
3 Moderate Priority
4 Low Priority
15 Satisfactory

Major Findings

1. Roofing

Moderate
Observation: Several shingles show signs of weathering, lifted edges, or granule loss.

Recommendation: Consult a qualified roofing contractor for evaluation and repair.
Approx. Age: 8 years
Type: Asphalt shingles
Location: Southwest roof slope

2. Electrical

High
Observation: A double-tapped breaker was observed in the main electrical panel.

Recommendation: Have a licensed electrician evaluate and correct the wiring configuration.
Panel Capacity: 200 Amp
Service Type: Underground
Priority: Safety concern

3. Plumbing

Low
Observation: Minor drip observed beneath the kitchen sink drain assembly.

Recommendation: Repair or replace drain connections as needed.
Water Heater: Gas
Approx. Age: 5 years
Location: Kitchen sink

4. HVAC System

Satisfactory
Observation: Heating and cooling systems operated normally during the inspection.

Recommendation: Continue routine maintenance and replace filters regularly.
Cooling: Central AC
Heating: Forced Air Gas
Thermostat: Functional

5. Foundation & Structure

Satisfactory
Observation: No significant structural movement was observed at the time of inspection.

Recommendation: Monitor minor cosmetic cracking and maintain proper drainage around the home.
Foundation Type: Slab
Construction: Wood frame
Drainage: Maintain slope away from structure

Systems Overview

Exterior

  • Roof coverings reviewed
  • Gutters functional
  • Minor caulking deterioration
  • Drainage reviewed

Interior

  • Walls and ceilings reviewed
  • Windows and doors tested
  • Floors inspected
  • Minor maintenance noted

Electrical

  • Main panel inspected
  • Sample outlets tested
  • GFCI protection checked
  • Smoke detectors present

Plumbing

  • Water supply reviewed
  • Drainage systems checked
  • Fixtures tested
  • Water heater reviewed

HVAC

  • Furnace operational
  • AC operational
  • Thermostat functional
  • Routine maintenance advised

Additional Services If Included

Thermal Imaging

No significant thermal anomalies detected at the time of inspection.

Satisfactory

Sewer Scope

Main sewer line appeared functional with no major obstructions observed.

Satisfactory

Radon Test

Result: 1.8 pCi/L
EPA action level: 4.0 pCi/L

Satisfactory

Crawl Space

Crawl space was accessible and appeared to be in satisfactory condition.

Satisfactory